Interface language
Appearance
Coordinate Import & Evaluation
Import 64 electrode coordinates and evaluate them as a separate layout, without running a region-layout search.
Coordinate file and evaluation conditions
Import a 64-electrode design in Ernie's native millimeter coordinate system. Points already in the forward bank use the original FEM results directly; new positions require a new FEM calculation. Digitized coordinates from other head models must first be registered.
Digitized coordinates and electrode name lists usually have no EEGLayoutLab region column. With a region count chosen, the 64 electrodes are divided by position into regions of balanced size, and the method is recorded in the coordinate source.
Select electrodes.tsv and coordsystem.json together. The region column is this software's zero-based region extension; electrodes.json may describe it. Coordinates must be in the Ernie native frame or an MNI template space, in mm. MNI coordinates are mapped onto Ernie's scalp with the SimNIBS nonlinear transform.
Digitized head-frame coordinates (for example CapTrak) need NAS, LPA and RPA landmarks in coordsystem.json, in mm, cm or m. They are aligned by the landmarks, fitted to Ernie's scalp and projected onto it. This places the montage on a template head; it is not an individual anatomical registration.
The file needs 64 electrodes and the Nz/LPA/RPA (or FidNz/FidT9/FidT10) landmarks. An .elc file declares its unit; an .sfp file has none, so choose the unit first. Files exported by EEGLayoutLab are read back unchanged.
Two columns, name and region, and 64 rows. Positions are the template positions of the SimNIBS 10-05 cap on Ernie's scalp, the same source as the standard 64-channel reference. T3, T4, T5 and T6 are read as T7, T8, P7 and P8.
Regional source power and noise structure fitted to real EEG recordings (eeglayoutlab prior). Once loaded it replaces the noise model; gains are relative to the area prior, where 1 means unchanged. Results apply only to data similar to those recordings.
One task runs at a time. Coordinate evaluation uses one thread, and results are saved in a separate cache. FEM calculations for new positions have a 10-minute limit.
Decision requirements
Shared requirement: field reconstruction, amplitude, and localization utility retention must each be at least 90%.
Changing requirements only reassesses existing metrics; it does not start a computation. Blank limits are not checked in individual mode.
Validation stages
Completed: single-head layout experiments, independent-source re-evaluation, and multiple noise controls. In progress: numerical and search-stability checks. Awaiting independent data: transfer of frozen layouts to new head models, measured-noise calibration, and simultaneous-recording comparisons.
View metric definitions and modeling methods